18649 - Acceptance Test Log


18649 Spring 2010
Group 7 - Justin Ray / justinr2

The table below describes the acceptance tests and summarizes the current acceptance test results.  For each submission, these results must be consistent with the code and test files submitted with that version of the portfolio.   Be sure to include all information listed in the project handouts.

Acceptance Test Parameters
Test Status
Test Results
Notes
-cc 10
-seed 1265810079949
all customers satisfied sodamachine-10-10.stats
This test identified issue #15 .
-cc 1000
-seed 1265811488163
all customers satisfied
sodamachine-100-5.stats
This test identified issue #16
-cc 1000
-seed 1265814975536
all customers satisfied sodamachine-100-6.stats

-cc 1000
-seed 1265815026934
all customers satisfied sodamachine-100-7.stats

-cc 1000
-seed 1265815200224
all customers satisfied sodamachine-100-0.stats


Note:  This table presents different information than the acceptance test log requirements for the elevator project because the soda machine passenger model and acceptance testing requirements are significantly less complex.  YOU MUST FOLLOW ALL THE PROJECT REQUIREMENTS FOR LOGGING ACCEPTANCE TESTS.  DO NOT USE THIS FORMAT OR COPY THIS TABLE.